QTi DALI 4X18 DIM

Product family benefits
  • System+ Guarantee available
  • Easy integration in luminaire thanks to same dimensions like DALI GI ECG
  • TouchDIM function for easy and inexpensive dimming of several ECGs
  • Same luminous flux with direct and alternating current
  • Dimming of amalgam lamps without flickering or reduced lifespan
  • Automatic restart after lamp replacement
DALI product features
  • Control via the DALI interface
  • Compliance with the DALI Version-1 and IEC 60929
  • Control input protected against overvoltage and polarity reversal (OSRAM ECG)
Touch DIM and Touch DIM Sensor function
  • Manual dimming without controller and with standard switches
  • Including memory function (double click) and soft start
Areas of application
  • Suitable for use in emergency lighting systems as per EN 50172/DIN VDE 0108-100
  • Installation in emergency lighting systems according to IEC 61347-2-3, appendix J
  • Industry
  • Open-plan offices, corridors and storage rooms
  • Public buildings
  • Sports halls and factories
  • Strip lighting
  • Suitable for luminaires of protection class I

References / Links
For more information on the system guarantee and the terms and conditions of the guarantee visit https://www.inventronics-light.com/multilevel-guarantees

Technical Data

Electrical data

Input voltage AC

198…264 V

Nominal voltage

220…240 V

Mains frequency

50…60 Hz

Input voltage DC

154…276 V

Efficiency in full-load

92 %

at 230 V, 50 Hz

Maximum output power

4 x 18 W

Operating frequency

40…100 kHz

Max. ECG no. on circuit breaker 10 A (B)

12

Type B

Max. ECG no. on circuit breaker 16 A (B)

19

Type B

Inrush current

35 A

Light technical data

Starting time

1.2 s

Optimized preheat start

Dimensions & weight

Length

360.0 mm

Width

40.0 mm

Height

21.0 mm

Mounting hole spacing, length

350.0 mm

Product weight

374.00 g

Cable cross-section, output side

0.5…1.5 / 0.5…1.0 mm²

Solid leads / Flexible

Cable cross-section, input side

0.5…1.5 / 0.5…1.0 mm²

Solid leads / Flexible

Temperatures & operating conditions

Ambient temperature range

0…+50 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

100000 h

At Tcase = 65°C at Tc point / 10% failure rate

Additional product data

Suitable for lamp power (4 lamps)

18 W

Capabilities

Dimming interface

DALI / Touch DIM / Touch DIM Sensor

Dimming range

1…100 %

Luminous flux

Dimmable

Yes

Overheating protection

Power reduction and switch off at T > 75 °C at the tc point

End of lamp life safety shutdown

EOL T.2

Suitable for fixtures with prot. class

I

Intended for no-load operation

No

Max. cable length to lamp/LED module

1.0 m

Certificates & standards

Approval marks – approval

VDE / VDE-EMC / EL / EAC / RCM / CCC

Standards

Acc. to EN 55015; EN 55022/Acc. to EN 61547/Acc. to EN 61000-3-2/Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN 55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to EN 61547/Acc. to IEC 62386-101:Ed1/Acc. to IEC 62386-102:Ed1

Type of protection

IP20

EEI – Energy Label

A1 BAT

Protection class

I

Logistical data

Commodity code

85041080900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

30-10-2023

Primary Article Identifier

4008321070050

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

817dc363-07f9-45ee-9832-150283f57074

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4008321070050 UNV

Unpacked

1 360mm x 40mm x 21mm 374.00g 0.30dm³
4008321070067 VS

Shipping box

20 380mm x 96mm x 206mm 7752.50g 7.51dm³

Downloads

Lamp-ECG Combination
DULUX F 18 W

Nominal current

0.31 A

Nominal wattage + Power loss

69.30 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1100 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

4

DULUX L 18 W

Nominal current

0.31 A

Nominal wattage + Power loss

69.30 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1200 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

4

L 18 W

Nominal current

0.31 A

Nominal wattage + Power loss

69.30 W

Power factor λ [PIM]

0.98

Luminous flux at 35 °C

1350 lm

Ambient temperature range [PIM] REM

Operation at up to -20 °C for all QTi (DALI) DIM-ECG possible. Lowest dimming position must be limited. Details see technical dimming brochure.

Number of lighting outlets

4

ECG_1.1 Ambient temperature for lifespan

40 °C

ECG_1.2 Ambient temperature for lifespan

50 °C

ECG_1.3 Ambient temperature for lifespan

60 °C

ECG_2.1 Tc point temperature for lifespa

55 °C

ECG_2.2 Tc point temperature for lifespa

65 °C

ECG_2.3 Tc point temperature for lifespa

75 °C

ECG_3.1 Temperature dependent lifespan

100000 h

ECG_3.2 Temperature dependent lifespan

100000 h

ECG_3.3 Temperature dependent lifespan

90000 h

Information about Family

If you need to install or modernize a lighting system with T8 lamps, the QUICKTRONIC INTELLIGENT DALI DIM T8 is an excellent option. It provides extensive DALI and TouchDIM functionalities, corridor function and a dimming range from 1 %...100 % (3 %...100 % with CFL). It is fit for SMART GRID, has a Fit for Emergency function and permits a very high number of switching cycles. Use QUICKTRONIC INTELLIGENT DALI DIM T8 with luminaires of protection class I for emergency lighting per EN 50172/DIN VDE 0108-100 and IEC 61347-2-3, appendix J, and for industrial lighting, office lighting, strip lighting, public buildings, factories, sports halls, corridors and storage rooms. This ECG’s many benefits include easy integration into luminaires, because it has the same dimensions as the DALI GI ECG, it also allows the dimming of amalgam lamps without harm or reduction in lamp life and provides automatic restart after lamp replacement.
Product family features
  • Corridor function for direct connection of ECG to common motion sensor
  • Corridor function with pre-programmed light program
  • Touch DIM function for free parameterization of light value and turn on time
  • Fit for SMART GRID for feedback of consumed mains power and lamp operating hours
  • Fit for emergency function for automatic detection of emergency lighting by ECG
  • Very low standby power consumption: < 0.5 W
  • Lifetime: > 100,000 h (for T = 65 °C at Tc)
  • Very high number of switching cycles: up to 300,000
  • Dimming range: 1…100 % (3…100 % with compact fluorescent lamp)
  • POWER2LAMP function for optimal matching of ECG power to lamp during lamp lifetime
  • Line frequency: 0 Hz, 50…60 Hz, rectified AC
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Height
Dimmable
Width
Dimming interface
Dimming range
Data sheet
QTi DALI 2X18 DIM
21.0 mm Yes 30.0 mm DALI / Touch DIM / Touch DIM Sensor 1…100 %
QTi DALI 3X18 DIM
21.0 mm Yes 40.0 mm DALI / Touch DIM / Touch DIM Sensor 1…100 %
QTi DALI 4X18 DIM
21.0 mm Yes 40.0 mm DALI / Touch DIM / Touch DIM Sensor 1…100 %