OTI DX 75/220…240/600 D NFC L

Product family benefits
  • Versatile non-isolated DEXAL LED driver up to 75 W due to flexible output characteristic
  • Integrated DEXAL Bus power supply for sensors and wireless radios
  • Simplified luminaire design for wireless lighting control system and sensors
  • Locking and unlocking of luminaire/driver data
  • Advanced luminaire/driver data (power, energy, operating hours…) for analytics
  • Prepared for DiiA Specification Parts -250, -251, -252 and -253
  • Fully programmable via T4T software (NFC, DALI Interface)
  • Very high efficiency
  • Protection against 4 kV burst and 1.5 kV surge voltage (L-N)
  • Wide operating range up to 600 mA
Areas of application
  • Linear lighting for office, education, industry, storage areas and retail
  • DEXAL, easy connection to different partner BMS systems
  • Suitable for "Works with OSRAM DEXAL" partner components
  • Suitable for luminaires of protection class I
German innovation awards 2019 winner Luminaire information Monitoring data osram-dam-5000620

Technical Data

Electrical data

Nominal input voltage

220…240 V

Mains frequency

0/50/60 Hz

Input voltage AC

198…264 V

Input voltage DC

176…276 V

Current set

DALI / NFC / LEDset / Programmable

Total harmonic distortion

< 10 %

At full load

Power factor λ

0.46C…0.98

Full load at 230 V

Efficiency in full-load

93 %

at 230 V, 50 Hz

Device power loss

5.25 W

Inrush current

27 A

twidth = 200 µs (measured at 50 % Ipeak)

Max. ECG no. on circuit breaker 10 A (B)

15

Max. ECG no. on circuit breaker 16 A (B)

24

Surge capability (L/N-Ground)

2 kV

Surge capability (L-N)

1.5 kV

Nominal output voltage

54…240 V

U-OUT (working voltage)

< 250 V

Nominal output current

120…600 mA

Default output current

60 mA

LEDset deactivated

Output current tolerance

±5 %

Output ripple current (100 Hz)

< 4 %

Output PSTLM

≤1

Output SVM

≤0.4

Nominal output power

6.5…75 W

Maximum output power

75 W

Galvanic isolation

Non isolated

DEXAL Peak Supply Current

60 mA

Power loss in stand-by mode

<0.25 W

DEXAL"OFF"

DEXAL Supply Voltage

15 V

DEXAL Guaranteed Supply Current

53 mA

Dimensions & weight

Mounting hole spacing, length

350.0 mm

Product weight

243.00 g

Cable cross-section, input side

0.5…1.5 mm²

Solid or flexible leads

Cable cross-section, output side

0.5…1.5 mm²

Solid or flexible leads

Wire preparation length, input side

8.0…9.0 mm

Wire preparation length, output side

8.0…9.0 mm

Length

360.0 mm

Width

30.0 mm

Height

21.0 mm

Colors & materials

Casing material

Metal

Temperatures & operating conditions

Ambient temperature range

-25…+55 °C

Maximum temperature at tc test point

75 °C

Maximum at the Tc-point

Max.housing temperature in case of fault

110 °C

Temperature range at storage

-40…+85 °C

Permitted rel. humidity during operation

5…85 %

Maximum 56 days/year at 85 %

Lifespan

ECG lifetime

50000 / 100000 h

At maximum Tc = 75°C / 10% failure rate / At Tc = 65°C / 10% failure rate

ECG ambient temperature (ta)

55 °C

45 °C

Temperature at the measuring point tc (°C)

75 °C

65 °C

ECG lifespan (h)

50000 h

Max. 10% failure rate at tc max and input voltage 230 VAC

100000 h

Max. 10% failure rate at tc max and input voltage 230 VAC

Additional product data

Encapsulated

No

Capabilities

Programming interface

DEXAL, NFC, LEDset

Dimmable

Yes

Dimming interface

DALI-2 / DEXAL

Dimming range

1…100 %

Dimming method

Full analogue dimming

Selectable by Tuner4TRONIC

Overheating protection

Automatic reversible

Overload protection

Non-reversible

Short-circuit protection

Automatic reversible

No-load proof

Yes

Intended for no-load operation

No

Max. cable length to lamp/LED module

2.0 m

Output wires must be routed as close as possible to each other

Suitable for fixtures with prot. class

I

Suitable for emergency lighting

Yes

Type of connection, input side

Push terminal

Type of connection, output side

Push terminal

Control interface

DEXAL

Constant lumen function

Programmable

Number of channels

1

DALI-2 Diagnostic Data

Yes

DALI-2 Energy Data

Yes

Programming

Programming device

DALI magic / NFC Scanner

Tuner4TRONIC

Yes

Tuner4TRONIC Field App

Yes

Box programming

Yes

Programmable features

Constant Lumen

Yes

Operating Current

Yes

Driver Guard

Yes

Soft Switch Off

Yes

Dim to Dark

Yes

TouchDIM + Sensor

Yes

DEXAL Power Supply Unit

Yes

Emergency Mode

Yes

DALI-2 Luminaire Data

Yes

Lamp Operating Time

Yes

Certificates & standards

Approval marks – approval

CE / EL / VDE-ENEC / VDE-EMC / EAC / CCC / BIS / RCM

Standards

Acc. to EN 61347-1/Acc. to EN 61347-2-13/Acc. to EN 62384/Acc. to EN 61000-3-2/Acc. to EN 61000-3-3/Acc. to EN 61547

Type of protection

IP20

Logistical data

Commodity code

85044083900

Environmental information


Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)

Date of Declaration

20-11-2023

Primary Article Identifier

4052899590403

Candidate List Substance 1

Lead

CAS No. of substance 1

7439-92-1

Safe Use Instruction

The identification of the Candidate List substance is sufficient to allow safe use of the article.

Declaration No. in SCIP database

62c5caf0-ea2e-4828-bb8c-cd92a8441e8e

Packaging information

EAN

Unit

Piece

Dimension l x w x h

Weight

Volume

4052899590403 UNV

Unpacked

1
4052899590410 VS

Shipping box

20 385mm x 160mm x 100mm 5031.00g 6.16dm³

Downloads

Information about Family

Future proof – ready for wireless applications.

This product is industry ready thanks to a high surge / burst (up to 4kV) and a low standby. For luminaire info and monitoring data the DiiA standards -251, -252, and -253 are integrated and the device is fully digitally programmable by DALI, NFC and LT2. It’s also possible to select AM or AM/PWM dimming.
Product family features
  • Line frequency: 0 Hz | 50 Hz | 60 Hz
  • Supply voltage: 220…240 V
  • Constant Lumen Output (CLO)
  • Monitoring of luminaire operating parameters
  • Non-isolated drivers
Ecodesign regulation information:
Intended for use with LED modules.
The forward voltage of the LED light source shall be within the defined operating window of the control gear in all operating conditions including dimming if applicable.

Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.

Products

Sort by:
Product
Nominal output voltage
Nominal output current
Length
Width
Height
Data sheet
OTI DX 35/220…240/400 D NFC L
54…240 V 75…400 mA 360.0 mm 30.0 mm 21.0 mm
OTI DX 75/220…240/600 D NFC L