EBN-OS /230
Product family benefits
- Increases maximum number of ECG per automatic cutout by factor 2.5
- Flexible use depending on the size of the installation
- Simple installation
Areas of application
- Suitable for all POWERTRONIC and selected OPTOTRONIC control gears
Technical Data
Electrical data
System wattage
0.60 W
Line current
16 A
Nominal voltage
230 V
Mains frequency
50 60 Hz
Surge capability (L-N)
2 kV
Power input
0.6 W
Surge capability (L/N-Ground)
2 kV
Dimensions & weight
Length
58.0 mm
Width
18.0 mm
Height
88.0 mm
Product weight
75.00 g
Mounting depth
55.0 mm
Colors & materials
Casing material
Plastic
Temperatures & operating conditions
Ambient temperature range
-10 +40 °C
Additional product data
Predecessor EAN
4006584548019
Successor EAN
4062172123242
Capabilities
Type of installation
35 mm standard rail
Type of fixing
Snap in clip
Dimmable
No
Mains terminals
Socket terminals with captive screws M3.5
Secondary terminals
Socket terminals with captive screws M3.5
Certificates & standards
Standards
Acc. to IEC 801-4 level 4/Acc. to IEC 801-5 level 3/Acc. to VDE 0110 Gr C/250V
Logistical data
Commodity code
85041080900
Environmental information
Information according Art. 33 of EU Regulation (EC) 1907/2006 (REACh)
Date of Declaration
24-03-2023
Primary Article Identifier
4006584548019 | 4062172123242
Candidate List Substance 1
No declarable substances contained
Declaration No. in SCIP database
In work
Packaging information
EAN |
Unit |
Piece |
Dimension l x w x h |
Weight |
Volume |
---|---|---|---|---|---|
4006584548019 |
UNV
| 1 | 58mm x 18mm x 88mm | 75.00g | 0.09dm³ |
4062172123259 |
FS2
| 10 | 190mm x 95mm x 66mm | 788.00g | 1.19dm³ |
4062172123266 |
VS
| 100 | 410mm x 310mm x 280mm | 8480.00g | 35.59dm³ |
Downloads
Information about Family
EBN-OS is an inrush current limiter for use with all POWERTRONIC, and some OPTOTRONIC, ECGs. It works as a retrofit for DIN rail to DIN EN 60417 and has an operating frequency of 50
60 Hz and maximum continuous load of 16 A. EBN-OS lets you increase the maximum number of ECGs per automatic cutout by a factor of 2.5 and is simple to install. You can use it flexibly, according to the size of the light installation.
Product family features
- Retrofit for DIN rail to DIN EN 60417
- Operating frequency: 50 60 Hz
- Maximum continuous load: 16 A
- Limitation time: 70 ms
- Number of switching cycles: up to 10,000
Ecodesign regulation information:
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. For this purpose, collection points for recycling centres and take-back systems (CRSO) are available from retailers or private disposal companies, which accept separate control gear and light sources free of charge. In this way, raw materials are conserved and materials are recycled.
Products
Product |
|
|
|
|
|
Data sheet | ||
---|---|---|---|---|---|---|---|---|
EBN-OS /230
|
88.0 mm | 230 V | 0.60 W | 0.6 W | No |